What was found
LEFT FLAP SUSTAINED DAMAGE FROM HAIL. THREE DENTS REQUIRED REPAIRS. FIRST DENT DAMAGE MEASURES 1/2 INCH IN DIAMETER AND .003 INCH IN DEPTH, LOCATED 5 1/2 INCH FROM TRAILING EDGE AND AT STATION 209.2. SECOND DENT DAMAGE MEASURE 3/8 INCH IN DIAMETER AND .003 IN DEPTH, LOCATED 2 1/2 INCH FROM TRAILING EDGE AND AT STATION 183.2. THE THIRD DENT DAMAGE MEASURES 3/8 INCH IN DIAMETER AND .005 INCH IN DEPTH, LOCATED 3 1/4 INCH FROM TRAILING EDGE AND AT STATION 71.8. COMPLETED COMPOSITE REPAIRS TO AILERON SKIN IAW EO#S51031.