SDR MALA060347

Service difficulty report · Seal · Bac AVRO146RJ85A

Difficulty date
May 26, 2006
Submitted
June 7, 2006
Operation
Air carrier
Aircraft
N523XJ
Make and model
Bac AVRO146RJ85A
Aircraft serial
E2348
Aircraft time
15,254 hours, 14,177 cycles
Part
Seal
Part number
521449
Part serial
F9840810
Condition
Damaged
Location
Hydraulic Sys
Stage of operation
UK
How discovered
O
Nature of condition
J
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

YELLOW SYSTEM HI TEMP ILLUMINATED, POM PROCEDURES FOLLOWED. WHILE TURNING OFF AC PUMP, AC PUMP FAIL ILLUMINATED MOMENTARILY. NOTED COOLING OIL FOR NR 2 ENGINE DRIVEN PUMP BYPASSING PUMP DUE TO DAMAGED SEALS. REPLACED NR 2 HUDRAULIC PUMP AND ASSOCIATED SEALS. PERFORMED GROUND RUN. ALL CHECKS GOOD. ILLUMINATION OF AC PUMP FAIL LIGHT WHEN SELECTING PUMP OFF IS NORMAL INDICATION. P/N 521449, S/N ON F9840810.