SDR MALA100096

Service difficulty report · Power Supply · Saab 340B

Difficulty date
July 15, 2010
Submitted
July 16, 2010
Operation
Air carrier
Aircraft
N448XJ
Make and model
Saab 340B
Aircraft serial
340B448
Aircraft time
25,513 hours, 28,211 cycles
Part
Power Supply
Condition
Malfunctioned
Location
Emergency Lights
Stage of operation
IN
How discovered
C
Nature of condition
L
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

CIRCUIT BREAKER L8 TRIPPED IN FLIGHT FOLLOWED RESET PROCEDURE POM 3.8.1 CIRCUIT BREAKER TRIPPED AGAIN AFTER 15 MIN OF FLIGHT L8 = EMERGENCY LIGHTS CABIN & EXT CONTROL. FERRY AIRCRAFT FOR TROUBLESHOOTING AND REPAIR L-8 CIRCUIT BREAKER POPPED. INSPECTED ACFT AND FOUND CIRCUIT BREAKER L8 POPPED COLLARD CIRCUIT BREAKER L8 AND FOUND ACFT SAFE FOR INTENDED FERRY FLIGHT FOR FURTHER TROUBLESHOOTING AND REPAIR. DURING TROUBLESHOOTING FOUND EMERGENCY LIGHTS POWER SUPPLY 24LN BAD. R& R EMERGENCY LIGHTS POWER SUPPLY 24LN IAW AMM 33-50-10. OPS CHECK GOOD MX NOTIFIED PN OFF/ON 3301-51, SN OFF 2182, SN ON 1445.