What was found
DURING INITIAL CLIMBOUT FROM MSP "EMER LTS ON" WHILE STATUS MESSAGE ILLUMINATED AND WAS INTERMITTENT. BOTH F/A STATED THE OVERWING EMERGENCY EXIT LIGHTS (ALL 4) WERE FLICKERING. IN CRUISE FLIGHT ALL INDICATIONS WERE NORMAL. DURING DESCENT LIGHTS CAME ON ONCE. REMAINDER OF FLIGHT ALL INDICATIONS WERE NORMAL. CONTACTED DISPATCH AND MXC. FOLLOWED POM. T/S AND FOUND DEFECTIVE NR 5 EMER LIGHT BATTERY CHARGER FS 752. REMOVED AND REPLACED EPSU BATTERY PACK P/N ON & OFF 2013-1A, S/N ON 100681, AND REPLACED BATTERY CHARGER P/N ON&OFF 11-0049, S/N ON 22618, BOTH AT NR 5 POSITION. OPERATIONAL CHECK OF EPSU GOOD, REF CRJ900 AMM 33-51-17.