What was found
EMERGENCY LIGHT INOPERATIVE AT RT SERVICE DOOR EXTERIOR. DEFERRED EMERGENCY INOPERATIVE LIGHT IAW 33-51-2A. MXC NOTIFIED. ENTERED INTO MMO2. PLACARDED. R & R EPSU BATTERY PACK NR 2 IAW AMM 33-51-17. OPS CHECKED GOOD.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
EMERGENCY LIGHT INOPERATIVE AT RT SERVICE DOOR EXTERIOR. DEFERRED EMERGENCY INOPERATIVE LIGHT IAW 33-51-2A. MXC NOTIFIED. ENTERED INTO MMO2. PLACARDED. R & R EPSU BATTERY PACK NR 2 IAW AMM 33-51-17. OPS CHECKED GOOD.