What was found
STATION 280 BULKHEAD CORRODED ON LT SIDE OF FLT DECK ENTRANCE ON UPPER SIDE OF 280 BEAM, MARKED DOT 68A006. REMOVED 3 BLIND RIVETS TO FACILITATE THE REMOVAL OF CORROSION. REMOVED CORROSION FROM STA 280 BULKHEAD IAW SRM 51-21-06. UT INSPECTION SHOWED A MATERIAL LOSS OF .001 USING UT TESTER AAR 521401 DUE DATE 04/11/12. REMAINING MATERIAL IS WITHIN LIMITS IAW SRM 53-00-00. REMAINING MATERIAL IS .031. REINSTALLED 3 BLIND RIVETS PN CR3223-5-2. TAG NR B84867 IAW SRM 51-42-00. REAPPLIED FINISH TO AREA IAW SRM 51-21-16.