As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
NOSE GEAR SAFE (GREEN) LIGHT DID NOT ILLUMINATE INTRANSIT LIGHT OUT. HYD PUMP STOPPED WHEN MAINS WENT GREEN AFTER RECYCLE GEAR WHEN FUNCTIONED NORMALLY. CLEANED "UP" AND "DN" LOCK SWITCHES AND LUB SWING GEAR 10 TIMES. NO FAULT NOTED NOSE GEAR SAFE GREEN LIGHT COMES ON WITH GEAR DOWN AND LOCK AMBER LIGHT COMES WITH GEAR UP AND LOCK IAW AMM 32-30-00-05.