What was found
DURING A C-CHECK INSPECTION IN BNA, MAINTENANCE NOTED CORROSION TO STRINGER 31, P/N 85310984, AT STATION 182, FRAME 31. REPAIRS WERE COMPLETED BY FABRICATING AND INSTALLING A REPAIR DOUBLER IAW RD 53-925 AND SRM 51-10-100. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING A C-CHECK INSPECTION IN BNA, MAINTENANCE NOTED CORROSION TO STRINGER 31, P/N 85310984, AT STATION 182, FRAME 31. REPAIRS WERE COMPLETED BY FABRICATING AND INSTALLING A REPAIR DOUBLER IAW RD 53-925 AND SRM 51-10-100. (M)