What was found
MSP - DURING A SCHEDULED INSPECTION, MAINTENANCE FOUND AT WS 27.03 RT AFT WING RIB TRAILING EDGE (PN 27-31523), A 0.375 INCH CRACK. COMPLETED REPAIR PER FAC SRM 57-90-10, PAGES 3-6, REV. NOVEMBER 1, 1994, BY FABRICATING AND INSTALLING A 0.050 INCH BY 4.00 INCH BY 2.50 INCH REPAIR DOUBLER TO AFFECTED AREA. (X)