SDR MALA976069

Service difficulty report · Hyd Pump · Saab 340B

Difficulty date
March 28, 1998
Submitted
March 26, 2000
Operation
Air carrier
Aircraft
N427XJ
Make and model
Saab 340B
Aircraft serial
427
Part
Hyd Pump
Part number
4018502
Condition
Failed
Location
Nlg Ww
Stage of operation
AP
Nature of condition
J
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

ON APPROACH, SELECTED GEAR HANDLE DOWN, PUMP RAN, GEAR UNSAFE LIGHT ILLUMINATED, GEAR DOORS DID NOT OPEN, RECYCLED GEAR AND STILL UNSAFE. CONTACTED MAINTENANCE CONTROL AND PULLED THE T-HANDLE AND PUMPED THE GEAR DOWN, GEAR CAME DOWN WITH THREE GREENS. AIRCRAFT LANDED WITHOUT INCIDENT. MAINTENANCE REPLACED HYDRAULIC PUMP, RELAY 15GA (PN M83536/6-022L) AND SOCKET 15GA-31 (PN RSE120060). ALL CHECKS GOOD.

More about the Saab 340B