What was found
DURING HEAVY CHECK, LOCATED DENT IN FUSELAGE STA 634. MAINTENANCE COMPLETE STEP 3.2.1 FOR THE DYE PENETRANT/EDDY CURRENT INSPECTION OF THE SURROUNDING PANEL AND ADJACENT AND WEB AREAS OF FRAME AT STA 632.112, REF NTM 51-08-00 AND 51-06-00. REFERENCE STEP 3.3.2 IF NO FURTHER DAMAGE IS NOTED THE SENT IS SMOOTH, IT CAN BE ACCEPTED AS IS. NO FURTHER ACTION IS REQUIRED.