SDR MALA976479

Service difficulty report · Pump · Saab 340B

Difficulty date
May 19, 1999
Submitted
March 26, 2000
Operation
Air carrier
Aircraft
N412XJ
Make and model
Saab 340B
Aircraft serial
340B412
Part
Pump
Part number
4018502
Condition
Failed
Location
Hyd System
Stage of operation
CL
Nature of condition
O
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

GEAR DID NOT RETRACT UNTIL HYD PUMP SWITCH WAS SELECTED TO OVERRIDE, PUMP WORKS PROPERLY IN THE OVERRIDE POSITION. MAINTENANCE CONTROL DEFERRED AUTO PUMP CONTROL SYSTEM. MAINTENANCE REPLACED HYD PUMP PER SR340 AMM 29-10-10. OPS AND LEAK CHECKS GOOD.