What was found
RETURNED TO FIELD DUE TO RUD 1 AND RUD 2 INOP MESSAGES IN FLIGHT. MX REPLACED THE NR 2 HYD SYSTEM PRESSURE SWITCH. A/C DEPARTED WITHOUT FUTHER INCIDENT.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
RETURNED TO FIELD DUE TO RUD 1 AND RUD 2 INOP MESSAGES IN FLIGHT. MX REPLACED THE NR 2 HYD SYSTEM PRESSURE SWITCH. A/C DEPARTED WITHOUT FUTHER INCIDENT.