Service difficulty report · Smoke Detector · Cndair CL6002C10

Difficulty date
February 22, 2013
Submitted
March 12, 2013
Operation
Air carrier
Aircraft
N522LR
Make and model
Cndair CL6002C10
Aircraft serial
10262
Aircraft time
15,645 hours, 11,100 cycles
Part
Smoke Detector
Condition
False Indication
Location
Aft Lavatory
Stage of operation
DE
How discovered
O
Nature of condition
N
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

SMOKE WARNING IN AFT LAVATORY DURING FLT. RESET DETECTOR SYSTEM, CHECKED GOOD. INSPECTING BOTH ENGINE PRESSURE REGULATING VALVES TO ENSURE NO LEAKS BEHIND FAN BLADES AND INSPECTED THE APU COMPARTMENT FOR ANY OIL OR FUEL LEAKS. INSPECTED ALL THREE BLEED SOURCES, BOTH PACKS AND RESET DETECTOR PERFORMED BLEED RUNS WITH ALL THREE BLEED SOURCES WITH NO DEFECTS FOUND AND INSPECTED ENGINES WITH NO LEAKS FOUND.