What was found
CORROSION ON FLOOR BEAM (UPPER/AFT FLANGE) IN STA FS 280 AND 11 RBL AT PAX CABIN FWD WET AREA. (W1) (CPAX) FLOOR BEAM FS 280.00 RT WAS REPLACED, PER CRJ900 SRM 51-42-06-001-AO1 PAR 6 AND SRM 51-42-001-001-A01 PAR 8.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORROSION ON FLOOR BEAM (UPPER/AFT FLANGE) IN STA FS 280 AND 11 RBL AT PAX CABIN FWD WET AREA. (W1) (CPAX) FLOOR BEAM FS 280.00 RT WAS REPLACED, PER CRJ900 SRM 51-42-06-001-AO1 PAR 6 AND SRM 51-42-001-001-A01 PAR 8.