What was found
CORROSION ON FLOOR BEAM [UPPER/AFT FLANGE] IN STA FS=280 AND 11RBL TO 13RBL AT PAX FWD WET AREA|FLOOR BEAM WAS REPLACED FRO A NEW ONE PER CRJ900 SRM 51-92-06-001-001-A01 AND SRM 51-42-71-001-001-A01
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORROSION ON FLOOR BEAM [UPPER/AFT FLANGE] IN STA FS=280 AND 11RBL TO 13RBL AT PAX FWD WET AREA|FLOOR BEAM WAS REPLACED FRO A NEW ONE PER CRJ900 SRM 51-92-06-001-001-A01 AND SRM 51-42-71-001-001-A01