What was found
CORROSION REMOVED BY BLENDING AND FOUND TO BE WITHIN ALLOWABLE LIMITS IAW ERJ-175 SRM 53-23-11 AD2, DVI PERFORMED IAW NDTM TASK 51-05-00-214-801-A, NO FINDINGS SURFACE WAS REPROTECTED I.A.W SRM 51-23-04, 51-23-05, 51-23-06, REMAINING THICKNESS 0.050", CORROSION LEVEL 1