What was found
DURING C1, C3 SCHEDULED MAINTENANCE INSPECTIONS OF FWD FUSELAGE SKINS, MULTIPLE DENTS FOUND O RH SIDE (QTY 9). THE DAMAGES ARE OUTSIDE THE ALLOWABLE LIMITS DEFINED IN ERJ175 SRM 53-10-01, AD02. AS PER ETD2026-170-003152 DISPOSITION-001 THE 9 DENTS WHERE FOUND AS PERMANENT ALLOWABLE DAMAGE. NO FURTHER ACTION REQUIRED.