What was found
DURING HEAVY CHECK, INSPECTIONS OF FWD CARGO CUTOUT CORROSION FOUND ON LOWER BEAM AFT SEAL REST BETWEEN FR 26 R/H AND FR 27 R/H, HAS BEEN REMOVED BY BLENDING IAW SRM 51-10-03. WITH IN LIMITS IAW SRM 53-21-11 AD01, MAX MATRL REMOVED .008" 10X MAG C/OUT "NO FAULT FOUND". REPROTECTED BLENDED AREA IAW SRM 51-23-04, SRM 51-23-05, SRM 51-23-06. REV #53- AUG-21-2025, NRC 4502583-8000-0021.