What was found
DURING HEAVY CHECK INSPECTIONS OF EXT SKIN, CORROSION AT FR 90 LT, BETWEEN STR 13 LT, REPAIRED BY BLENDING, SRM 51-10-03, FOUND WITHIN LIMITS IAW SRM 51-75-16, PARA 4, HFEC C/OUT NO FAULT FOUND AWS AND NDT REPORT TWO 47667-2 FOR DETAILS AND WORK PERFORMED. MAX MATERIAL REMOVED .001 REPROTECTED BLENDED AREA IAW SRM 51-23-04, SRM 51-23-05, AND SRM 51-23-06. REV 53, NRC 4502654-3000-0003. CORROSION LEVEL 1.