What was found
DURING HEAVY CHECK, INSPECTIONS OF INTERNAL FLOOR STRUCTURE, CF ILL, CORRODED MID SHEAR PANEL AT FR 78 TO FR 88, RBL 11 TO LBL 11 REMOVED AND REPLACED !AW ERJ 175 SRM 51-42-01. NRC #4502703-2000-0282. REV 45 DATED MAY-28-2021.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING HEAVY CHECK, INSPECTIONS OF INTERNAL FLOOR STRUCTURE, CF ILL, CORRODED MID SHEAR PANEL AT FR 78 TO FR 88, RBL 11 TO LBL 11 REMOVED AND REPLACED !AW ERJ 175 SRM 51-42-01. NRC #4502703-2000-0282. REV 45 DATED MAY-28-2021.