What was found
FWD CARGO DOOR, LOWER MAIN SILL, OUTER CHORD, STA 500, RBL 44.0. DURING INSPECTION AT IAI, THE CORROSION WAS FOUND ON OUTER CHORD P/N 143T8205-3. THE CORROSION WAS REMOVED, PER SRM 53-00-15, ALLOWABLE DAMAGE. AFTER THE REMOVAL THE MINIMUM THICKNESS IS 0.150" (0.190" INITIAL), 0.040" THICKNESS REDUCED.