What was found
FUSELAGE SKIN EXTERNAL FUSELAGE SKIN AT STA 632, STR-26R SECTION 43. SHOP FOUND BLEND OUT IN FASTENERS ZONE IN UPPER SKIN OF LAP JOINT IN FUSELAGE SKIN AT THE DATUM LOCATION. ACCORDING TO SRM 53-00-01 ALLOWABLE DAMAGE 1, BLEND OUT IS NOT APPLICABLE IN FASTENERS AREA.