What was found
FUSELAGE SKIN, STA 1351-STA 1375, STR 29R-30R AND STA 1417-STA 1427, STR 32L-33L: THIS REA INCLUDES SEVERAL NRC’S: M0049, M0051, M0063. MAINTENANCE FOUND EXISTING BLEND OUTS ON FUSELAGE EXTERNAL SKIN THAT IS NOT PERMITED IAW SRM 53-00-01, FIG 101, ADL 1, TABLE I, DETAIL II. (FALL ON RIVETED AREA) M0049: NOM THICKNESS: 0.207”, MIN THICKNESS: 0.0204. M0051: NOM THICKNESS: 0.207”, MIN THICKNESS: 0.02. M0063: NOM THICKNESS: 0.183”, MIN THICKNESS: 0.0180. ALL BLEND OUTS FALL ON RIVETED AREA.