SUB FLOOR CRACKED OUT AROUND RIVET HOLE AT STATION 200, 5.5 INCHES OUTBOARD OF NR 3 SEAT TRACK. FABRICATED AND INSTALLED FILLER AND DOUBLER.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
SUB FLOOR CRACKED OUT AROUND RIVET HOLE AT STATION 200, 5.5 INCHES OUTBOARD OF NR 3 SEAT TRACK. FABRICATED AND INSTALLED FILLER AND DOUBLER.