What was found
VENTRAL STAIRWAY DOOR JAMB SPLICE ANGLE AT STATION 908 RIGHT HAS SHORT E.D. ON SEVERAL FASTENER HOLES. REMOVED SPLICE ANGLE AND INSTALLED DOUBLER/SPLICE ANGLE.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
VENTRAL STAIRWAY DOOR JAMB SPLICE ANGLE AT STATION 908 RIGHT HAS SHORT E.D. ON SEVERAL FASTENER HOLES. REMOVED SPLICE ANGLE AND INSTALLED DOUBLER/SPLICE ANGLE.