What was found
MKE - LEFT WING LOWER SURFACE HAD 2 FASTENERS LEAKING FUEL AT STR 19 BETWEEN STA 214 - STA 240. REMOVED FASTENERS, REMOVED TO OVERSIZE AND FABRICATED REPAIR BUSHINGS. INSTALLED BUSINGS AND FASTENERS. (X)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
MKE - LEFT WING LOWER SURFACE HAD 2 FASTENERS LEAKING FUEL AT STR 19 BETWEEN STA 214 - STA 240. REMOVED FASTENERS, REMOVED TO OVERSIZE AND FABRICATED REPAIR BUSHINGS. INSTALLED BUSINGS AND FASTENERS. (X)