What was found
CRACK ON FRAME AT STATION 256, LONGERON 8 LEFT. REMOVED FASTENERS AND DAMAGED AREA, FABRICATED AND INSTALLED FRAME SPLICE AND ANGLE.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CRACK ON FRAME AT STATION 256, LONGERON 8 LEFT. REMOVED FASTENERS AND DAMAGED AREA, FABRICATED AND INSTALLED FRAME SPLICE AND ANGLE.