What was found
THREE FASTENER HOLES NOT FILLED, STATION 634, INTERCOSTAL AT LONGERON 10 RIGHT. REMOVED, FABRICATED AND INSTALLED REPAIR DOUBLER.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
THREE FASTENER HOLES NOT FILLED, STATION 634, INTERCOSTAL AT LONGERON 10 RIGHT. REMOVED, FABRICATED AND INSTALLED REPAIR DOUBLER.