What was found
CORROSION ON ANGLE BRACKET ON AFT SIDE OF LEFT LAV FLOORBEAM AT STATION 996 UNDER U-CHANNEL SUPPORT, 19 INCHES RIGHT OF CUSP. REMOVED, FABRICATED AND INSTALLED ANGLE.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORROSION ON ANGLE BRACKET ON AFT SIDE OF LEFT LAV FLOORBEAM AT STATION 996 UNDER U-CHANNEL SUPPORT, 19 INCHES RIGHT OF CUSP. REMOVED, FABRICATED AND INSTALLED ANGLE.