What was found
FORWARD ENTRY SUB FLOOR WEB HAS (3) 1 INCH CRACKS STATION 195 LBL 27, 30 & 40. FABRICATED AND INSTALLED NEW WEB.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FORWARD ENTRY SUB FLOOR WEB HAS (3) 1 INCH CRACKS STATION 195 LBL 27, 30 & 40. FABRICATED AND INSTALLED NEW WEB.