What was found
FORWARD ENTRY SUBFLOOR WEB HAS LIGHT CORROSION AROUND GALLEY MOUNT STATION 217 RBL 11. REMOVED DAMAGE, FABRICATED AND INSTALLED REPAIR DOUBLER.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FORWARD ENTRY SUBFLOOR WEB HAS LIGHT CORROSION AROUND GALLEY MOUNT STATION 217 RBL 11. REMOVED DAMAGE, FABRICATED AND INSTALLED REPAIR DOUBLER.