What was found
LONGERON 16 RIGHT AT STATION 965 HAS ONE BADLY ELONGATED HOLE. REMOVED DAMAGED AREA, LOCATED AND DRILLED NEW SECTION OF LONGERON, FABRICATED, LOCATED, DRILLED AND INSTALLED SPLICE REPAIR.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
LONGERON 16 RIGHT AT STATION 965 HAS ONE BADLY ELONGATED HOLE. REMOVED DAMAGED AREA, LOCATED AND DRILLED NEW SECTION OF LONGERON, FABRICATED, LOCATED, DRILLED AND INSTALLED SPLICE REPAIR.