What was found
GOUGES AND CORROSION ON INNER SKIN AND ANGLE BRACKETS OF LOWER BACK SIDE OF DOOR JAMB AFT PIT STATION 945-889. BLENDED CORROSION AND GOUGES. FABRICATED AND INSTALLED LOWER JAMB/INTERCOSTAL BRACKET. INSTALLED WEB STRAPS AT LONGERON 28 RIGHT AND 29 RIGHT.