What was found
CORROSION ON LONGERON 24 LEFT AT STATION 1361 CORROSION IS ON WASHERS ON RIVETS AND TWO SPOTS ARE ON THE LONGERON BELOW FRAME DOT 100. -- REMOVED LONGERON 24 LEFT, FABRICATED AND DRILLED LONGERON AND SPLICE FITTINGS AND REINSTALLED 8 HI-LOCS FROM EXISTING STIFFENER AND INSTALLED LONGERON AND FITTINGS.