What was found
WEB ON STATION 200 FLOOR BEAM UNDER OUTBOARD LEFT VERTICAL SUPPORT IS CORRODED. -- REMOVED DAMAGED AREA, FABRICATED DOUBLER AND FILLER AND INSTALLED REPAIRED DOUBLER.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
WEB ON STATION 200 FLOOR BEAM UNDER OUTBOARD LEFT VERTICAL SUPPORT IS CORRODED. -- REMOVED DAMAGED AREA, FABRICATED DOUBLER AND FILLER AND INSTALLED REPAIRED DOUBLER.