What was found
DURING INSPECTION, FOUND FORMER AT STA 897 AND L16R CRACKED AT UPPER AND LOWER EDGES. MAINTENANCE REMOVED AND REPLACED FORMER IAW SRM 53-01 PG 1. ALSO, FABRICATED AND INSTALLED NEW FITTING IAW DAC DRWG 3959083. RETURNED A/C TO SERVICE.