What was found
DURING INSPECTION, FOUND FLOORBEAM AT STA 256, 275, 408, AND 465 CHAFED FROM FLOOR CENTER PANELS. MAINTENANCE FABRICATED AND INSTALLED WEAR STRIP REPAIR IAW SRM 53-05 FIG 20A, RETURNED A/C TO SERVICE.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING INSPECTION, FOUND FLOORBEAM AT STA 256, 275, 408, AND 465 CHAFED FROM FLOOR CENTER PANELS. MAINTENANCE FABRICATED AND INSTALLED WEAR STRIP REPAIR IAW SRM 53-05 FIG 20A, RETURNED A/C TO SERVICE.