What was found
DURING D-CHECK, FOUND FLOOR PANEL CORRODED RT SIDE STA 120-STA 160. REPLACED MOST OUTBOARD HAT CHANNEL IAW SRM 53-01.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING D-CHECK, FOUND FLOOR PANEL CORRODED RT SIDE STA 120-STA 160. REPLACED MOST OUTBOARD HAT CHANNEL IAW SRM 53-01.