What was found
FOUND DAMAGED SKIN AROUND FWD ENTRANCE DOOR HOLD OPEN HOOK RECEPTACLE. INSTALLED DOUBLER REPAIR IAW SRM 53-04, FIG 24.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FOUND DAMAGED SKIN AROUND FWD ENTRANCE DOOR HOLD OPEN HOOK RECEPTACLE. INSTALLED DOUBLER REPAIR IAW SRM 53-04, FIG 24.