What was found
FOUND CENTER FLOOR BEAM SUPPORT AT STA 917 TO 996 HAS MODERATE CORROSION AROUND SCREW HOLES. REPLACED FLOOR SUPPORT IAW SRM 53-11-3, FIG 11.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FOUND CENTER FLOOR BEAM SUPPORT AT STA 917 TO 996 HAS MODERATE CORROSION AROUND SCREW HOLES. REPLACED FLOOR SUPPORT IAW SRM 53-11-3, FIG 11.