What was found
DURING CERT INSP, FOUND CABIN CENTER FLOOR BEAM UPPER CHANNEL WITH MODERATE CORROSION FROM STA 917 TO 965. REPLACED THE SECTION OF FLOOR BEAM IAW SRM 53-01, PG 1 AND 53-11-3, FIG 11.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING CERT INSP, FOUND CABIN CENTER FLOOR BEAM UPPER CHANNEL WITH MODERATE CORROSION FROM STA 917 TO 965. REPLACED THE SECTION OF FLOOR BEAM IAW SRM 53-01, PG 1 AND 53-11-3, FIG 11.