What was found
DURING INSP, A 1.25 INCH CRACK FOUND IN RT ELEVATOR UPPER SPAR CAP AT STA XE151. COMPLETED A REPAIR IAW SRM 55-02 FIG 9, CONFIGURATION -503.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING INSP, A 1.25 INCH CRACK FOUND IN RT ELEVATOR UPPER SPAR CAP AT STA XE151. COMPLETED A REPAIR IAW SRM 55-02 FIG 9, CONFIGURATION -503.