What was found
DURING D-CHECK, FOUND REPAIR OF LONGERON 2L AND 2R AT STA 897 NEED EVALUATION FOR REWORK. MAINTENANCE REMOVED REPAIR ON LONGERONS 2L AND 2R AT STA 897 AND INSTALLED SPLICE REPAIR IAW SRM 53-02 FIG 2.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING D-CHECK, FOUND REPAIR OF LONGERON 2L AND 2R AT STA 897 NEED EVALUATION FOR REWORK. MAINTENANCE REMOVED REPAIR ON LONGERONS 2L AND 2R AT STA 897 AND INSTALLED SPLICE REPAIR IAW SRM 53-02 FIG 2.