What was found
DURING D-CHECK, FOUND U-CHANNEL SUPPORT FWD END FITTING CORRODED BEYOND LIMITS AT STA 604 TO 610 BETWEEN LONGERONS 29R TO 30. MAINT FABRICATED AND INSTALLED END FITTINGS IAW SRM 51-10-04 AND 51-30.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING D-CHECK, FOUND U-CHANNEL SUPPORT FWD END FITTING CORRODED BEYOND LIMITS AT STA 604 TO 610 BETWEEN LONGERONS 29R TO 30. MAINT FABRICATED AND INSTALLED END FITTINGS IAW SRM 51-10-04 AND 51-30.