What was found
FLOORBEAM AT FS 916 WAS FOUND CHAFED FROM THE FLOORBOARDS FROM RBL 20 - LBL 20. BLENDED AREA OF BEAM, FABRICATED REPAIR STRAP IAW SRM 53-05 FIG 20, INSTALLED STRAP IAW SRM 51-30.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FLOORBEAM AT FS 916 WAS FOUND CHAFED FROM THE FLOORBOARDS FROM RBL 20 - LBL 20. BLENDED AREA OF BEAM, FABRICATED REPAIR STRAP IAW SRM 53-05 FIG 20, INSTALLED STRAP IAW SRM 51-30.