What was found
THE STATION 1089 CANTED FRAME FOUND WITH A CORRODED WEB AT LONGERON 12L. BLENDED CORROSION OUT OF LIMITS, FABRICATED REPAIR FILLER AND DOUBLER, INSTALLED REPAIR.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
THE STATION 1089 CANTED FRAME FOUND WITH A CORRODED WEB AT LONGERON 12L. BLENDED CORROSION OUT OF LIMITS, FABRICATED REPAIR FILLER AND DOUBLER, INSTALLED REPAIR.