SDR MYWA110140

Service difficulty report · Sensor · Boeing 73781Q

Difficulty date
December 27, 2011
Submitted
December 30, 2011
Operation
Air carrier
Aircraft
N733MA
Make and model
Boeing 73781Q
Aircraft serial
30619
Aircraft time
28,202 hours, 10,167 cycles
Part
Sensor
Condition
Dirty
Location
Cabin Temp
Stage of operation
NR
How discovered
O
Nature of condition
O
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

ETOPS SIGNIFICANT SYSTEM: FRM # 216-440-00 AUTO TEMPERATURE CONTROL TOO HOT, CANNOT MAKE COOLER IN AUTO OR MANUAL MODE CONT CABIN. ACCOMPLISHED FIM TASK 21-61 TASK 844 INITIAL EVALUATIONS FOUND NO DEFECTS AUTO TEMP CONTROL OPS CHECKS NORMAL IAW 21-61-15 NO DEFECTS NOTED. ACCOMPLISHED FIM TASK 21-61 TASK 864 ACCOMPLISHED PACK/ZONE TEMP CONTROLLERS BITE TEST IAW 21-60 TASK 801 NO FAULTS NOTED. IN REF TO FTD-21-06001 CHECKED FLIGHT DECK MUFFLER IAW 21-22-05 NO DEFECTS NOTED. IN REF TO FTD-21-03005 CLEANED AND SWAPPED MIX MANIFOLD TEMP SENSORS IAW 21-51-51, OPS CHECK NORMAL AUTO TEMP CONTROL CHECKS NORMAL.

More about the Boeing 737-81Q