What was found
CORROSION FOUND ON R2 SERVICE DOOR SILL, BODY STATION 964 RBL 43 NEXT TO AFT DRAIN AREA. R2 DOOR SILL CHORD REMOVED AND REPLACED IAW SRM 51-10- 02, HOLES PICKED UP PER SRM 51-40-05 REV 34.