What was found
CABIN FLOOR STRUCTURE CHANNEL AT BS 260-270, BL 0 FOUND CORRODED ON TOP SURFACE. CHANNEL REMOVED AND REPLACED IAW SRM 51-10-02, HOLES PICKED-UP PER SRM 51-40-05. FASTENER INSTALLED PER SRM 51-40-02 REV 35.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CABIN FLOOR STRUCTURE CHANNEL AT BS 260-270, BL 0 FOUND CORRODED ON TOP SURFACE. CHANNEL REMOVED AND REPLACED IAW SRM 51-10-02, HOLES PICKED-UP PER SRM 51-40-05. FASTENER INSTALLED PER SRM 51-40-02 REV 35.